产品型号:PX01008
标准编号:BS EN60204-1, BS EN746-2
应用领域:
检测目的:Heat Release Rate
行业标准: BS British Standards Institute
The micro calorimeter can determine basic chemical thermal values and predict the fire resistance of materials in a matter of minutes. This technique can quickly determine parameters such as specific heat release rate (W/g), combustion heat (J/g), and ignition temperature (°C) on very small samples (1-10mg) with low cost, high accuracy, and typical repeatability of ±5%.
ASTM D7309-2007: Standard Test Method for Determining the Flammability of Plastics and Other Solid Materials by Microcombustion Calorimeter
EMC 89/336/EEC: Electromagnetic compatibility 89/336/EEC
LVD 72/23/EEC
BS EN 60204-1: Safety of machinery - Electrical equipment for machinery - Part 1: General requirements
BS EN 746-2: Industrial thermal processing equipment. Safety requirements for combustion and fuel handling systems
Equipment No.: PX01008
Dimension: 343(W)×663(D)×1560(H)mm
Power Supply: AC220V,16A
Weight: APPR.80kg
Gas Source: Purity above 99.99% oxygen and nitrogen compressed air
Integrated structure design, beautiful and generous
Combustion furnace: program to control the temperature of combustion furnace heating to the specified temperature, constant temperature, temperature drift does not exceed 5K/h. Equipped with overtemperature protection device to protect the safety of equipment and personnel during the test
Temperature range: room temperature -1000℃, imported electric heating wire, over temperature protection, high-performance heating elements, longer service life
Multiple cooling devices, easy to heat the instrument
Sample heating rate can be adjusted
The sample cup is equipped with a temperature sensor
The sample cup can be automatically moved to the combustion furnace, special design to ensure soft contact
The equipment provides anaerobic and aerobic environmental high temperature decomposition test mode
High precision MFC (mass flow controller), control air, oxygen, nitrogen gas intake, response time less than 1S, accuracy F.S±1%.
Imported oxygen sensor, range: 0-100%, T90< 6 s. Accuracy ±0.1%, linear range: F.S±1%
The equipment is fast in testing and convenient in testing
LABVIEW data acquisition software, configuration computer control
Displays the running status of devices in real time
Calibrate equipment and store calibration data results
Collect data during the test.
Heat release rate coefficient (W/g), combustion heat (J/g), ignition temperature (℃) and other parameters were calculated.