PX08002 Lithium battery performance tester

产品型号:PX08002

标准编号:

应用领域:

检测目的:Heat Release RateSmoke Density

行业标准:

The lithium battery combustion performance test system refers to UL 9540A and calculates the heat release rate according to the principle of oxygen consumption. It is used to test the combustion behavior and performance of lithium battery under thermal runaway condition, and measure the key data such as heat release rate, total heat release and smoke density

产品标准产品规格产品特点使用单位

产品标准

ANSI/CAN/UL 9540A: 2019

产品规格

Equipment No.: PX08002


Floor area: 1300(L)×6500(W)×7000(H)mm


Control cabinet dimension: 650(L)×675(W)×1750(H)mm


Gas analysis cabinet dimension: 650(W)×675(D)×1750(H)mm


Power supply: AC380V 15KW 50Hz AC220V 5KW 50Hz


Weight:APPR. 20 kg


Gas Source: ammonia, standard gas, methanol


产品特点

  • The smoke collecting hood and smoke pipe are made of 304 stainless steel, the diameter of smoke pipe is 400mm, and the flow equalizer device is used before and after the smoke exhaust pipe to ensure the uniform flow of gas


  • The exhaust capacity of the fan is 4kg/s, equipped with an independent frequency control cabinet, the fan frequency can be adjusted continuously to reduce signal interference, and the fan damping system is included


  • The test section adopts live interface, which can be used to connect temperature thermocouple, sampling tube, differential pressure probe, optical path system, flow velocity calibration device, infrared temperature sensor, etc., which is easy to disassemble and maintain, and easy to operate


  • Equipped with OMEGA thermocouple for measuring smoke tube and ambient temperature


  • The optical path system includes the transmitting end and the receiving end. The light source adopts imported bulbs and is equipped with a voltage regulator for power supply. The receiving end adopts imported optical path receiver, the signal is stable and reliable, and has multi-stage automatic optical path calibration and verification function


  • Differential pressure is measured using standard compliant bidirectional probe and Setra differential pressure sensor


  • Equipped with special oil pan to verify the stability and accuracy of heat release test system


  • An independent Kc verification device is optional for measuring the distribution of wind speed in the smoke tube


  • Optional heat flux test system, temperature acquisition system, to meet the requirements of different levels of testing


  • Adopt independent standard gas sampling system, built-in multistage filtration, pressure regulation and flow regulation device, adopt imported condenser and desiccants to pretreat the gas, to ensure that the gas into the analyzer is dry, clean and stable, the pipeline adopts all stainless steel structure, the overall structure is beautiful, generous, long service cycle. Used in conjunction with the sampling tube of the test section


  • Paramagnetic type 0₂ analyzer and infrared CO₂ analyzer, oxygen range 0-25%, CO₂:0-10%, CO: 0-1%; Oxygen accuracy < 0.02%, repeatability < 0.01%, CO₂ accuracy 0.1ppm, CO accuracy 0.1ppm, repeatability 0.1ppm. Response time < 8s


  • Electrical control adopts self-designed electrical cabinet, built-in integrated touch computer, with Siemens control module to achieve function control and data collection.


  • The upper computer software is designed based on NI Labview platform, equipped with a variety of calibration modes, real-time calculation and waveform display of volume flow rate, heat release rate, smoke generation and other parameters, can achieve data recording, calibration report and test report output view and other functions.