PRODUCT
product2
产品型号:PX02002
标准编号:GB/T18380.11, GB/T18380.12
应用领域:
电线电缆
检测目的:Flame Spread
Flammability
行业标准:
GB中国标准
The single wire and cable combustion tester is applied to the vertical flame spread test of a single wire, cable or optical cable, and can also check the burning condition of dripping objects under the condition of 1Kw flame.
IEC 60332-1-1, 2, 3: Testing of electrical and fiber optic cables under fire conditions
GB/T 18380.11, 12: Combustion test of cables and optical cables under flame conditions
GB/T 5169.14: 1Kw nominal premixed flame
Equipment No.: PX02002
Equipment Dimension: 300(W)×450(D)×1200(H)mm
Console Dimension: 500(W)×400(D)×250(H)mm
Power Supply: AC 220V,2 A
Weight: APPR.80kg
Gas Source: More than 95% propane; dry compressed air
All stainless steel box, inner cavity height 1200mm, width 300mm, depth 450mm
The control box and the combustion box are separated to reduce the impact of combustion heat on electrical components and improve the service life of the equipment
Pure copper premixed blowtorch meets standard requirements and can provide 1Kw fire source
The burner can be adjusted vertically and 45 degrees to meet the requirements of test fire and fire source correction.
Through the slide rail module, the positioning mechanism can quickly and accurately reach the firing position.
High voltage pulse automatic ignition, stable and reliable ignition, high safety
The vortex spring structure clamp can easily clamp samples of different wire diameters
Equipped with imported precision rotor flowmeter to control gas and air flow
Equipped with brand pressure gauge and pressure regulating valve to adjust gas and air pressure, equipped with solenoid valve to control gas on and off, to ensure the safety of equipment use.
Programmable logic controller (PLC) + touch screen control, can realize automatic control/detection/calculation/data storage
Experiment time, fire time can be set by yourself, software automatically timed
The specific flame impact time arrival reminder function and the function of automatically cutting off the gas source without an experiment within 10 minutes ensure safe use.
Optional 1Kw flame calibration package, imported brand thermocouple measurement accuracy ± 0.1 ℃, can automatically generate calibration curve and judge.