在线客服 电话 微信 置顶
电话:400-086-0699

微信客服

微信客服

首页>PRODUCT > Flammability>VW-1 Wire and Cable Combustion Resistance Test Chamber

PX02009 VW-1 Wire and Cable Combustion Resistance Test Chamber

产品型号:PX02009

标准编号:GB/T5169.5-2008, ASTM D5025, UL1581

应用领域: 电线电缆

检测目的:Flame SpreadFlammability

行业标准: GB中国标准 ASTM美国材料与试验协会 其他测试标准

The wire and cable fire resistance test chamber is a special testing machine for testing the fire resistance of wire insulators or coverings according to the requirements of UL1581/UL2556, ASTM D 5025/ASTM D5207. It is used to test the fire resistance of wire and cable insulation layers.

产品标准产品规格产品特点使用单位

产品标准

UL1581 sect 1080.1~1080.14: Flame Retardant Part of the Reference Standard for Electric Wires, Cables and Cords


UL2556 Clause 9: Fire retardant part of test methods for wire and cable


ASTM D 5025: Specification for Laboratory Burners for Small Scale Burn Tests of Plastics


GB/T 5169.15: Test flame 500W flame device and confirmation test method



产品规格

Equipment No.:  PX02009

Dimension:          2010(W)×1200(D)×2150(H)mm  

Power Supply:  AC220V,5A

Weight:               APPR.150kg

Gas Source:        Methane with a purity of more than 98%



产品特点

  • The size of the combustion box is 4 cubic meters, and the frame structure is made of thickened steel plate.


  • A translation observation window is installed on the front of the box, which is convenient for observing the test process and changing samples. The side door is opened for the operator to enter the box for equipment cleaning and maintenance.


  • A smoke exhaust device is installed on the top, which can be automatically opened to discharge the test exhaust gas after the test. An inlet baffle is installed on the side wall, which automatically opens to supplement clean air when exhausting smoke, without manual operation.


  • Equipped with American HUMBOLDT Tirell fire source, inner diameter 9.5±0.3mm, in line with ASTM D5025 standard


  • The burner is installed on the sliding seat, which can realize automatic adjustment of various angles through the motor, and automatic completion of multiple flame shocks.


  • High voltage pulse automatic ignition, stable and reliable ignition, high safety


  • Equipped with stainless steel vertical sample holder, durable and resistant to high temperature and flame shock. The installation method is convenient and can clamp samples of different wire specifications.


  • Equipped with imported precision rotor flowmeter to control gas flow, and equipped with imported differential pressure meter to measure the back pressure of the burner.


  • Equipped with brand pressure gauge and pressure regulating valve to adjust gas pressure, equipped with solenoid valve to control gas on and off, to ensure the safety of equipment use.


  • Programmable logic controller (PLC) + touch screen control, can realize automatic control/detection/calculation/data storage


  • Test time, fire time can be set by yourself, software automatically timed


  • Linear burning rate (V) PLC calculation, data touch screen display and save


  • Optional 500W flame calibration package, imported brand thermocouple measurement accuracy ± 0.1 ℃, can automatically generate calibration curve and judge.